Advantage of using System ID extension in Switch Bridge ID

The format of the original 802.1d bridge ID was redefined from two byte priority + MAC address to System ID extension mainly due to the advent of multiple spanning trees as supported by Per VLAN Spanning Tree Plus (PVST+) and IEEE 802.1s Multiple Spanning Trees (MST). With the old-style bridge ID format, a switch’s bridge ID for each STP instance (possibly one per VLAN) was identical if the switch used a single MAC address when building the bridge ID. Having multiple STP instances with the same bridge ID was confusing, so vendors such as Cisco Systems used a different Ethernet BIA for each VLAN when creating the old-style bridge IDs. This provided a different bridge ID per VLAN, but it consumed a large number of reserved BIAs in each switch. 

The System ID Extension allows a network to use multiple instances of STP, even one per VLAN,  but without the need to consume a separate BIA on each switch for each STP instance. The System ID Extension field allows the VLAN ID to be placed into what was formerly the last 12 bits of the Priority field. A switch can use a single MAC address to build bridge IDs, and with the VLAN number in the System ID Extension field still have a unique bridge ID in each VLAN. The use of the System ID Extension field is also called MAC address reduction, because of the need for many fewer reserved MAC addresses on each switch.




Comments

Popular posts from this blog

What is Cisco Supervisor Engine?

Supervisor Engine is a module that is installed in the Cisco Chassis-based Catalyst Switches or Routers. Supervisor engine contains nearly all the same components of a fixed Cisco Switches or Routers. These Supervisor engines come in a variety of different types with different functionalities and are installed in the Switches/Router Chassis as per requirements of the network types.

Benefits of Supervisor Engines
By installing Latest Supervisor Engines in your existing investments (Switches and Routers) you can scale system performance and integrate next-generation services into your Networks.
Within a single multilayer switch chassis, two supervisor modules with integrated route processors can be used to provide hardware redundancy. If an entire supervisor module fails, the other module can pick up the pieces and continue operating the switch.
The supervisor engine contains the following integrated daughter cards that perform forwarding and routing and provide the protocols supported …

GNS3 Docker Error while creating node: Docker has returned an error: Cannot connect to host docker:80

Error while creating node: Docker has returned an error: Cannot connect to host docker:80 ssl:False [No such file or directory]

After adding docker template for Alpine Linux in gns3, you get above mentioned message when you want to use alpine linux in GNS3.

To get rid of this message you have to install Docker by following below link
curl -fsSL https://get.docker.com/ | sh

If you do not have curl installed then instal curl first with below command.apt-get install curl
After installing Docker you need to add your user name in the docker group with the following command. $ sudo usermod -aG docker your_username

Verify if the docker service is started with following command$ service docker status
If docker is not started then start with following command $ sudo service docker start
Logout from GNS3 Virtual Machines and log back. Start gns3 and use alpine linux.

a file I/O error has occurred while accessing vmware converter

While converting physical Windows 7 machine to Virtual machine of infrastructure type, I got this error. The error seems it is unable to read/write source or destination datastore.

I have installed VMware-converter-en-6.2.0-8466193 on Windows 7 physical machine with option locally selected. (not at server/client option)

All of my ESXi servers are connected to the vCenter Server, so I had to use vCenter Server's IP address to send this physical machine to the virtual world.

The issue i found was with the dns resolution to the vCenter Server's hostname. Since I am not using the same dns server on the Windows 7 client machine. So I updated the host entries manually for the vCenter Server's hosname to it IP address.

After adding dns eteries to the hostfile of windows 7, I am not getting this "a file I/O error has occurred while accessing vmware converter" and the migration has started.