Skip to main content

How to send emails to undisclosed recipients?

Do you want to send emails to multiple recipients and want to keep their identities confidential from each other? Have you ever received an email that was addressed to “undisclosed recipient”? This is a way to send to a group of people without exposing their identities to others.

When you need to send to a group of people and want to keep their identity confidential, you can utilize the “BCC” function in your e-mail system.

Bcc recipients get a copy of the email, but their email address is automatically deleted at delivery. Nobody except you and the Bcc: recipient will know that they got a copy, and their email address will not be exposed.

Whether you use Yahoo, MSN, Gmail, or any other email service, do the followings:

• in the “To:” field, put: Undisclosed Recipients <youruserlogin@youremail.com>
then replace youruserlogin and youremail.com with your own e-mail address

• put all your email recipients in the “BCC” box, separate by comma. For example: yourfirstfriend@yahoo.com, yoursecondfriend@hotmail.com, etc

• compose your message as usual

• when finished, simply click the send… and you are done…

Comments

Popular posts from this blog

What is Cisco Supervisor Engine?

Supervisor Engine is a module that is installed in the Cisco Chassis-based Catalyst Switches or Routers. Supervisor engine contains nearly all the same components of a fixed Cisco Switches or Routers. These Supervisor engines come in a variety of different types with different functionalities and are installed in the Switches/Router Chassis as per requirements of the network types.

Benefits of Supervisor Engines
By installing Latest Supervisor Engines in your existing investments (Switches and Routers) you can scale system performance and integrate next-generation services into your Networks.
Within a single multilayer switch chassis, two supervisor modules with integrated route processors can be used to provide hardware redundancy. If an entire supervisor module fails, the other module can pick up the pieces and continue operating the switch.
The supervisor engine contains the following integrated daughter cards that perform forwarding and routing and provide the protocols supported …

GNS3 Docker Error while creating node: Docker has returned an error: Cannot connect to host docker:80

Error while creating node: Docker has returned an error: Cannot connect to host docker:80 ssl:False [No such file or directory]

After adding docker template for Alpine Linux in gns3, you get above mentioned message when you want to use alpine linux in GNS3.

To get rid of this message you have to install Docker by following below link
curl -fsSL https://get.docker.com/ | sh

If you do not have curl installed then instal curl first with below command.apt-get install curl
After installing Docker you need to add your user name in the docker group with the following command. $ sudo usermod -aG docker your_username

Verify if the docker service is started with following command$ service docker status
If docker is not started then start with following command $ sudo service docker start
Logout from GNS3 Virtual Machines and log back. Start gns3 and use alpine linux.

a file I/O error has occurred while accessing vmware converter

While converting physical Windows 7 machine to Virtual machine of infrastructure type, I got this error. The error seems it is unable to read/write source or destination datastore.

I have installed VMware-converter-en-6.2.0-8466193 on Windows 7 physical machine with option locally selected. (not at server/client option)

All of my ESXi servers are connected to the vCenter Server, so I had to use vCenter Server's IP address to send this physical machine to the virtual world.

The issue i found was with the dns resolution to the vCenter Server's hostname. Since I am not using the same dns server on the Windows 7 client machine. So I updated the host entries manually for the vCenter Server's hosname to it IP address.

After adding dns eteries to the hostfile of windows 7, I am not getting this "a file I/O error has occurred while accessing vmware converter" and the migration has started.